Design and supply of 2 Nos Dehumidifier unit and 70000 CMH /41000 CFM AHU plug fan with IE-3, Chilled water piping, ducting, thermal insulation, Supply of Hepa Filter with housing, return air raiser, VFD, replacement of coil and the Area Validation As per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply installation testing commissioning of 32000 CMH AHU, 8000 CMH Ventilation, BMS System, Chilled water piping, Ducting, Thermal insulation, Supply of Hepa Filter with housing, Return air raiser, VFD, replacement of coil & Validation. Area Validation As per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply of 09 Nos Air handling units, with plug fan in IE-3, flame proof & non flame proof type AHU. Hepa housing with gel seal Hepa filter, ducting, CHW & Hot water piping and thermal insulation works, ducting and SS-304 piping, DC unit flexible piping (In food grade) along with controlling. Area Validation As per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply of 07 Nos Air handling units, with plug fan in IE-3, flame proof & non flame proof type AHU. Hepa housing with gel seal Hepa filter, ducting, CHW & Hot water piping and thermal insulation works, ducting and SS-304 piping along with controlling. Area Validation As per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply of 11 Nos Air handling units 2 Nos AHU cum dehumidifier system, with plug fan in IE-3, flame proof & non-flame proof type AHU. Hepa housing with gel seal HEPA filter, ducting, CHW & Hot water piping and thermal insulation works, ducting, and SS-304 piping along with controlling. Area Validation As per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
We have replaced the existing installed DIDW belt driven blower with EC Blower (Electronically Commutated) in the Air Handling Unit with controller. Monthly saving is INR 2Lac amount in monthly power consumption.
Supply of Hepa Filters, AHU Retro fitment, Ventilation system, ducting, piping & thermal insulation works.
Supply of AHUs Unit, Humidifier System, Heater Bank, Ducting, Piping, Thermal Insulation, Ventilation System & Validation- New Mouth Wash Facility.
Supply of AHU unit with DX type Outdoor Unit along with copper piping, Ducting & Thermal Insulation.
HVAC Deign (Heat Load) Works As per ISO.
Supply of AHU units, Dehumidifier systems, Heater Bank, AHU with VRF system and Modification & Up Gradation of the complete HVAC system as per USFD Guideline We have successfully completed the Injection Block, OSD Bloc, & Microbiology and Glycol Chiller, Chilled water, Hot water, Steam piping works, Ducting works, Thermal insulation, HVAC validation, Supply duct able SAC systems. Also, we have successfully completed the design build complete HVAC system. Area Validation As per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply of AHU units, Hepa Housing, Hepa Filter, Ventilation units, Grill, CHW piping, CHW Manifold, Steam line piping, Stem manifold, SS & GI ducting, Thermal insulation, FRP lining in duct joint for low RH Maintained.
Supply of AHU units, Hepa Housing, Hepa Filter, Ventilation units, Grill, CHW piping, CHW Manifold, Steam line piping, Stem manifold, SS & GI ducting, Thermal insulation, FRP lining in duct joint for low RH Maintained. The area Validation As per ISO- 14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply of Air handling units, Dehumidifier Units (ACD), Hepa Housing, Hepa Filter, Ventilation units, Grill, CHW piping, CHW Manifold, Steam line piping, Stem manifold, SS & GI ducting, Thermal insulation, FRP lining in duct joint for low RH Maintained. And HVAC Validation as per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply of 5 Nos of Air handling units in plug fan IE-3, Gel seal type Hepa housing Dismantling the existing AHU, Hepa Hosing, return air raiser, chilled water piping, hot water piping along with Access., Steam manifold, starter panel The area Validation As per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply of 04 Nos AHU units, 5.5Tr DX- 5Nos,11Tr DX 3 Nos Humidified system, duct mounted heater bank, Ducting, CHW piping, Supply of Hepa housing and return air raiser & HVAC Validation. The area Validation As per ISO-14644-3 and duct leakage testing as per SMACNA, DQ, IQ, OQ, PQ
Supply of AHU units, Hepa housing with gel seal Hepa filter, AHU With VRF outdoor, Duct mounted heater bank, humidifier systems aluminium GI ducting works, CHW & Hot water piping and thermal insulation works complete HVAC validation.
ARC- For Complete HVAC works FTY-2022-2023.
Supply of AHU units, Modification works in existing AHU, Raiser, CHW coil, CHW and Hot water piping Ducting & Thermal insulation works. Complete HVAC Validation.
Supply of AHU units, Modification works in existing AHU, Raiser, CHW coil, CHW and Hot water piping Ducting & Thermal insulation works. Complete HVAC Validation.
Supply installation testing commission of Ventilation units, chilled water coil.
Supply installation testing commissioning of AHU, Ducting, Condensing Unit system (Design build project).
Supply installation testing commissioning of Hepa Housing, CHW Piping, Ducting with testing AHU, Ducting, Condensing Unit system (Design build project).
Supply installation testing commissioning of AHU, Ducting, Condensing Unit system (Design. build project).
Air ducting, MS piping, Air shower, Hepa Housing Sel Seal Type, Raiser Grill.
Supply installation testing commissioning of AHU, Ducting, Condensing Unit system (Design build project).
OT Room HVAC Validation As per NABL revised guideline.
Charges for installation of FCU, Aluminium Ducting, GI Ducting, MS Piping & Thermal Insulation Works.
Air Balancing & AHU Performance Test.
Supply installation testing commissioning of AHUs, VRF System, Air Washer, Smoke Spill Type Fan Unit, Exhaust Unit, Dry/Wet Type Scrubber, Starter Panel VFD, BMS system, MS Ducting, GI Ducting, CHW Piping, Ducting Thermal insulation works, Fire Pro Coating Works.
Supply installation testing commissioning of AHUs, VRF Daikin Make duct able type SAC units, Air Washer, Smoke Spill Type Fan Unit, Exhaust Unit, Dry/Wet Type Scrubber, Starter Panel VFD, BMS system, MS Ducting, CHW Piping, Ducting Thermal insulation works.
Supply installation testing commissioning of AHU units. Chilled water piping, air washer system, Chilled water Pump Set, Mixing / Pressurization Tank & Thermal insulation, Ducting works.
Supply installation testing commissioning of chilled & condenser water pumps. Electrical panel VFD. MS piping, valves chiller installation works.
Day to Day Operation and HVAC low side non comprehensive AMC.
ARC- MS, SS, GI ducting, all type thermal insulation and Hepa housing, raiser installation, AHU & ACD shifting and installation works for all block.
Day to Day Operation and HVAC low side non comprehensive AMC.